next up previous contents index
Next: MODELLER updates Up: Introduction Previous: Running MODELLER   Contents   Index


Frequently asked questions (FAQ) and examples

Please also check the archive of the Users Mail List at http://salilab.org/archives/modeller_usage/.

  1. I want to build a model of a chimeric protein based on two known structures. Alternatively, I want to build a multi-domain protein model using templates corresponding only to the individual domains.

    This can be accomplished using the standard modeling routine. The alignment should be as follows when the chimera is a combination of proteins A and B:

    proteinA  aaaaaaaaaaaaaaaaaaaaaaaaaaaa----------------------------------
    proteinB  ----------------------------bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb 
    chimera   aaaaaaaaaaaaaaaaaaaaaaaaaaaabbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb
    

    In the PIR format the alignment file is:

    >P1;proteinA
    structureX:proteinA
    aaaaaaaaaaaaaaaaaaaaaaaaaaaa----------------------------------*
    >P1;proteinB
    structureX:proteinB
    ----------------------------bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb*
    >P1;chimera
    sequence:chimera
    aaaaaaaaaaaaaaaaaaaaaaaaaaaabbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb*
    

    If no additional information is available about the relative orientation of the two domains the resulting model will probably have an incorrect relative orientation of the two domains when the overlap between A and B is non-existing or short. To obtain satisfactory relative orientation of modeled domains in such cases, orient the two template structures appropriately before the modeling.

  2. I don't want to use one region of a template for construction of my model.

    The easiest way to achieve this is to not align that region of the template with the target sequence. If region 'bbbbbbbb' of the template should not be used as a template for region 'eeeee' of the target sequence the alignment should be like this:

    template  aaaaaaaaaaaaaaaaaaaaaaaa-----bbbbbbbbcccccccccccccccccccccccccccccc
    target    ddddddddddddddddddddddddeeeee--------ffffffffffffffffffffffffffffff
    

    The effect of this alignment is that no homology-derived restraints will be produced for region 'eeeee'.

  3. I want to define (additional) disulfide bonds in the target sequence because no equivalent disulfide bonds exist in any of the templates (in which case model.patch_ss_templates() cannot define them automatically).

    MODELLER can restrain disulfides in two ways: automatically (model.patch_ss_templates() or model.patch_ss()) and manually (model.patch()).

    If there is an equivalent disulfide bridge in any of the templates aligned with the target, the model.patch_ss_templates() command will generate appropriate disulfide bond restraints without any other input from the user. This command is run automatically by the 'model' script used for comparative modeling. The restraints include bond, angle and dihedral angle restraints. The SG -- SG atom pair also becomes an excluded atom pair that is not checked for an atom-atom overlap. The $\chi_i$ dihedral angle restraints will depend on the conformation of the equivalent disulfides in the template structure, as described in [Šali & Overington, 1994]. The command model.patch_ss() is similar, except that the current structure of MODEL, not templates, is used to guess the disulfide bonded CYS - CYS pairs.

    Explicit manual restraints can be added by the model.patch() command relying on the PRES DISU patching residue in the CHARMM topology file. When building comparative models with the automodel class, the `manual' disulfides should be defined in the automodel.special_patches() routine. The model.patch() command will establish the correct stereochemistry by relying on the CHARMM topology file and parameters to restrain the disulfide bond.

    It is better to use model.patch_ss_templates() than model.patch() where possible because the dihedral angles are restrained more precisely by using the templates than the general rules of stereochemistry.

    Some CHARMM parameter files have a multiple dihedral entry for the disulfide dihedral angle $\chi_3$ that consists of three individual entries with periodicities of 1, 2 and 3. This is why you see three feature restraints for a single disulfide in the output of the model.energy() command.

    from modeller.automodel import *
    
    # Redefine the special_patches routine to include the additional disulfides
    # (this routine is empty by default):
    class mymodel(automodel):
        def special_patches(self, aln):
            # A disulfide between residues 1 and 85 in chain A:
            self.patch(residue_type='DISU', residue_ids=('1:A', '85:A'))
            # A disulfide between residues 41 and 45 in chain B:
            self.patch(residue_type='DISU', residue_ids=('41:B', '45:B'))
    
    # This is as usual:
    log.verbose()
    env = environ()
    
    a = mymodel(env, alnfile='align1.ali', knowns='templ1', sequence='targ1')
    a.make()
    

  4. I want to explicitly force certain Pro residues to the cis $\omega$ conformation.

    MODELLER should usually be allowed to handle this automatically via the omega dihedral angle restraints, which are calculated by default.

    from modeller.automodel import *
    from modeller.scripts import cispeptide
    
    # Redefine the special_restraints routine to force Pro to cis conformation:
    # (this routine is empty by default):
    class mymodel(automodel):
        def special_restraints(self, aln):
            cispeptide(self.restraints, atom_ids1=('O:4', 'C:4', 'N:5', 'CA:5'),
                       atom_ids2=('CA:4', 'C:4', 'N:5', 'CA:5'))
    
    # This is as usual:
    log.verbose()
    env = environ()
    
    a = mymodel(env, alnfile='align1.ali', knowns='templ1', sequence='targ1')
    a.make()
    

  5. How can I select/remove/add a set of restraints?

    Restraints can be read from a file by model.restraints.append(), calculated by model.restraints.make(), or added ``manually'' by model.restraints.add(). model.restraints.pick() picks those restraints for objective function calculation that restrain the selected atoms only, as specified in the selected atoms set 1. Initially, all atoms are selected; this can be changed by the model.pick_atoms() command. model.restraints.make() command for some restraint types (e.g., distance) constructs restraints of the selected type between the atoms in the selected atoms sets 2 and 3. The 'automodel.homcsr()' routine contains examples of the model.pick_atoms() command when generating restraints by model.restraints.make(). There are also commands for adding and unselecting single restraints, model.restraints.add() and model.restraints.unpick(), respectively. If you do model.restraints.condense(), the unselected restraints will be deleted. This is useful for getting rid of the unwanted restraints completely.

  6. What are the different refinement levels really doing?

    There are two different optimization approaches available within MODELLER: variable target function method (VTFM) with conjugate gradients (CG) [Šali & Blundell, 1993] and molecular dynamics (MD) with simulated annealing (SA) [Šali & Blundell, 1993]. They can both be done to a different degree (with more or less cycles of CG and MD, faster or slower schedule for VTFM and SA). The exact details are best obtained from the scripts themselves because a detailed description would probably be longer than the scripts. For example, the QUANTA and INSIGHTII implementations of MODELLER have these three levels of optimization: no optimization (only copying coordinates from templates and building the undefined atoms using internal geometry information from the RTF entries); only VTFM with CG; also MD with SA. Most of the time (70%) is spent on the MD&SA part. Our experience is that when MD&SA are used, if there are violations in the best of the 10 models, they probably come from an alignment error, not an optimizer failure (if there are no insertions longer than approximately 15 residues).

  7. I want to change the default optimization schedule.

    See chapter 2 for the variables that could be changed and for their possible values.

    from modeller.automodel import *
    
    log.verbose()
    env = environ()
    
    a = automodel(env, alnfile='align1.ali', knowns='templ1', sequence='targ1')
    # Very thorough VTFM optimization:
    a.library_schedule = 1
    a.max_var_iterations = 300
    # Very thorough MD optimization:
    a.md_level = refine.very_slow
    # Repeat the whole cycle 3-times and do not stop unless obj.func. > 1E6
    a.repeat_optimization = 3
    a.max_molpdf = 1e6
    
    a.make()
    

  8. I want to build an all hydrogen atom model with water molecules and other non-protein atoms (atoms in the HETATM records in the PDB file).

    from modeller.automodel import *
    
    log.verbose()
    env = environ()
    env.io.hydrogen = env.io.hetatm = env.io.water = True
    
    a = allhmodel(env, alnfile='align1.ali', knowns='templ1', sequence='targ1')
    a.make()
    

  9. How do I build a model with water molecules or residues that do not have an entry in the topology and/or parameter files?

    Water molecules are indicated by 'w' in the alignment file and the special block residue ('BLK') that does not have entries in the residue topology and parameter libraries is indicated by '.'

    See Section 4.5.1 for information about block residues.

    from modeller.automodel import *
    
    log.verbose()
    env = environ()
    env.io.hetatm = env.io.water = True
    
    a = automodel(env, alnfile='align1.ali', knowns='templ1', sequence='targ1')
    a.make()
    

    The alignment file:

    >P1;templ1
    structureX:templ1:1::10::
    FAYVI/.wwww*
    
    >P1;targ1
    sequence:targ1:1::8::
    -GWIV/.ww-w*
    

  10. How do I define my own residue types, such as D-amino acids, special ligands, and unnatural amino-acids?

    This is a painful area in all molecular modeling programs. However, CHARMM and X-PLOR provide a reasonably straightforward solution via the residue topology and parameter libraries. MODELLER uses CHARMM topology and parameter library format and also extends the options by allowing for a generic ``BLK'' residue type (Section 4.5.1). This BLK residue type circumvents the need for editing any library files, but it is not always possible to use it. Due to its conformational rigidity, it is also not as accurate as a normal residue type. In order to define a new residue type in the MODELLER libraries, you have to follow the series of steps described below. As an example, we will define the ALA residue without any hydrogen atoms. You can add an entry to the MODELLER topology or parameter file; you can also use your own topology or parameter files. For more information, please see the CHARMM manual.

    1. Define the new residue entry in the residue topology file (RTF), say 'top_heav.lib'.

      RESI ALA      0.00000
      ATOM N    NH1    -0.29792
      ATOM CA   CT1     0.09563
      ATOM CB   CT3    -0.17115
      ATOM C    C       0.69672
      ATOM O    O      -0.32328
      BOND CB CA    N CA    O C    C CA    C +N
      IMPR C CA +N O     CA N C CB
      IC -C    N     CA    C         1.3551  126.4900  180.0000  114.4400    1.5390
      IC N     CA    C     +N        1.4592  114.4400  180.0000  116.8400    1.3558
      IC +N    CA    *C    O         1.3558  116.8400  180.0000  122.5200    1.2297
      IC CA    C     +N    +CA       1.5390  116.8400  180.0000  126.7700    1.4613
      IC N     C     *CA   CB        1.4592  114.4400  123.2300  111.0900    1.5461
      IC N     CA    C     O         1.4300  107.0000    0.0000  122.5200    1.2297
      PATC FIRS NTER LAST CTER
      

      You can obtain an initial approximation to this entry by defining the new residue type using the residue type editor in QUANTA and then writing it to a file.

      The RESI record specifies the CHARMM residue name, which can be up to four characters long and is usually the same as the PDB residue name (exceptions are the potentially charged residues where the different charge states correspond to different CHARMM residue types). The number gives the total residue charge.

      The ATOM records specify the IUPAC (i.e., PDB) atom names and the CHARMM atom types for all the atoms in the residue. The number at the end of each ATOM record gives the partial atomic charge.

      The BOND records specify all the covalent bonds between the atoms in the residue (e.g., there are bonds CB-CA, N-CA, O-C, etc.). In addition, symbol '+' is used to indicate the bonds to the subsequent residue in the chain (e.g., C - +N). The covalent angles and dihedral angles are calculated automatically from the list of chemical bonds.

      The IMPR records specify the improper dihedral angles, generally used to restrain the planarity of various groups (e.g., peptide bonds and sidechain rings). See also below.

      The IC (internal coordinate) records are used for constructing the initial Cartesian coordinates of a residue. An entry


      \begin{displaymath}
IC \quad a \quad b \quad c \quad d \quad d_{ab} \quad \alpha_{abc} \quad
\Theta_{abcd} \quad \alpha_{bcd} \quad d_{cd}
\end{displaymath}

      specifies distances $d$, angles $\alpha$, and either dihedral angles or improper dihedral angles $\Theta$ between atoms $a$, $b$, $c$ and $d$, given by their IUPAC names. The improper dihedral angle is specified when the third atom, $c$, is preceded by a star, '*'. As before, the '-' and '+' pre-fixes for the atom names select the corresponding atom from the preceding and subsequent residues, respectively. The distances are in angstroms, angles in degrees. The distinction between the dihedral angles and improper dihedral angles is unfortunate since they are the same mathematically, except that by convention when using the equations, the order of the atoms for a dihedral angle is $abcd$ and for an improper dihedral angle it is $acbd$.

      The PATC record specifies the default patching residue type when the current residue type is the first or the last residue in a chain.

    2. You have to make sure that all the CHARMM atom types of the new residue type occur in the MASS records at the beginning of the topology library: Add your entry at the end of the MASS list if necessary. If you added any new CHARMM atom types, you also have to add them to the radii libraries, 'modlib/radii.lib' and 'modlib/radii14.lib'. These libraries list the atomic radii for the different topology models, for the long range and 1-4 non-bonded soft-sphere terms, respectively. The full names of the files that are used during calculation are given by the environment variables $RADII_LIB and $RADII14_LIB.

    3. Optionally, you can add the residue entry to the library of MODELLER topology models, 'modlib/models.lib'. The runtime version of this library is specified by the environment variable $MODELS_LIB. This library specifies which subsets of atoms in the residue are used for each of the possible topologies. Currently, there are 10 topologies selected by topology.submodel (3 is default):

      1 ALLH all atoms
      2 POL polar hydrogens only
      3 HEAV non-hydrogen atoms only
      4 MCCB non-hydrogen mainchain (N, C, CA, O) and CB atoms
      5 MNCH non-hydrogen mainchain atoms only
      6 MCWO non-hydrogen mainchain atoms without carbonyl O
      7 CA CA atoms only
      8 MNSS non-hydrogen mainchain atoms and disulfide bonds
      9 CA3H reduced model with a small number of sidechain interaction centers
      10 CACB CA and CB atoms only

      The Ala entry is:

      #
               ALLH POLH HEAV MCCB MNCH MCWO CA   MNSS CA3H CACB
      *
      RESI ALA
      ATOM     NH1  NH1  NH1  NH1  NH1  NH1  #### NH1  #### ####
      ATOM     H    HN   #### #### #### #### #### #### #### ####
      ATOM     CT1  CT1  CT1  CT1  CT1  CT1  CT1  CT1  CAH  CT1
      ATOM     HB   #### #### #### #### #### #### #### CH3E ####
      ATOM     CT3  CT3  CT3  CT3  #### #### #### #### #### CT2
      ATOM     HA   #### #### #### #### #### #### #### #### ####
      ATOM     HA   #### #### #### #### #### #### #### #### ####
      ATOM     HA   #### #### #### #### #### #### #### #### ####
      ATOM     C    C    C    C    C    C    #### C    #### ####
      ATOM     O    O    O    O    O    #### #### O    #### ####
      

      The residue entries in this library are separated by stars. The '####' string indicates a missing atom. The atom names for the present atoms are arbitrary. The order of the atoms must be the same as in the CHARMM residue topology library. If a residue type does not have an entry in this library, all atoms are used for all topologies.

    4. You have to add the new residue type to the residue type library, 'modlib/restyp.lib'. The execution version of this file is specified by the environment variable $RESTYP_LIB. For the ALA residue,

        1 | ALA                 | A | ALA  | alanine
      

      You would generally add the new residue type at the end of the file. There are 5 fields in each line, separated by the '|' characters. The first field is an integer index corresponding to the integer residue type. The standard residue types have their indices smaller than 24. These are also the indices corresponding to the residue-residue substitution matrices. The second field contains the list of equivalent PDB or IUPAC 3-character residue names, used in the PDB files. A list rather than a single name is allowed because PDB can unfortunately use different names for the same residue type (e.g., water can be HOH, WAT, etc.). The third field gives a single character code for the residue type, which is used in the alignment file. This does not have to be unique, but if it is not unique you cannot use it in the alignment file. Any ASCII character is fine, it does not have to be a letter. If you run out of characters you can re-define the existing ones that you do not need. The fourth field gives the four-character CHARMM residue name, as specified in the RESI record of the topology library. The last field contains an optional comment.

      Every residue in the CHARMM topology file has to have an entry in the $RESTYP_LIB library, but not every residue entry in the $RESTYP_LIB library needs an entry in the residue topology file. If you need the edit the $RESTYP_LIB file, it is recommended that you change a copy of it, and provide that file to the environ() constructor.

    5. In general, when you add a new residue type, you also add new chemical bonds, angles, dihedral angles, improper dihedral angles, and non-bonded interactions, new in the sense that a unique combination of CHARMM atoms types is involved whose interaction parameters are not yet specified in the parameter library (see also Section 4.5.1). In such a case, you will get a number of warning and/or error messages when you generate the stereochemical restraints by the model.restraints.make() command. These messages can sometimes be ignored because MODELLER will guess the values for the missing parameters from the current Cartesian coordinates of the model. When this is not accurate enough or if the necessary coordinates are undefined you have to specify the parameters explicitly in the parameter library. Search for BOND, ANGL, DIHE, and IMPR sections in the parameters library file and use the existing entries to guess your new entries. Note that you can use dummy atom types 'X' to create general dihedral (i.e., X A A X) and improper dihedral angle (i.e., A X X A) entries, where A stands for any of the real CHARMM atom types. For the dihedral angle cosine terms, the CHARMM convention for the phase is different for 180${}^{o}$ from MODELLER's (Eq. 6.57). If you use non-bonded Lennard-Jones terms, you also have to add a NONB entry for each new atom type. If you use the default soft-sphere non-bonded restraints, you have already taken care of it by adding the new atom types to the $RADII_LIB and $RADII_LIB libraries.

  11. How do I define my own patching residue types?

    This is even messier than defining a new residue type. As an example, we will define the patching residue for establishing a disulfide bond between two CYS residues.

    PRES DISU         -0.36 ! Patch for disulfides. Patch must be 1-CYS and 2-CYS.
    ATOM 1:CB  CT2    -0.10 !
    ATOM 1:SG  SM     -0.08 !           2:SG--2:CB--
    ATOM 2:SG  SM     -0.08 !          /
    ATOM 2:CB  CT2    -0.10 ! -1:CB--1:SG
    DELETE ATOM 1:HG
    DELETE ATOM 2:HG
    BOND 1:SG 2:SG
    IC 1:CA  1:CB  1:SG  2:SG      0.0000    0.0000  180.0000    0.0000    0.0000
    IC 1:CB  1:SG  2:SG  2:CB      0.0000    0.0000   90.0000    0.0000    0.0000
    IC 1:SG  2:SG  2:CB  2:CA      0.0000    0.0000  180.0000    0.0000    0.0000
    

    The PRES record specifies the CHARMM patching residue type (up to four characters). As for the normal RESI residue types, patching residue types also have to be defined in the residue type library, 'modlib/restyp.lib'.

    The ATOM records have the same meaning as for the RESI residue types described above. The extension is that the IUPAC atom names (listed first) must be pre-fixed by the index of the residue that is patched. In this example, there are two CYS residues that are patched, thus the prefixes 1 and 2. When using the model.patch() command, the order of the patched residues specified by residue_ids must correspond to these indices (this is only important when the patch is not symmetric, unlike the 'DISU' patch in this example).

    DELETE records specify the atoms to be deleted, the two hydrogens bonded to the two sulfurs in this case.

    The BOND and IC (internal coordinate) records are the same as those for the RESI residues, except that the atom names are prefixed with the patched residue indices.

  12. Is it possible to restrain secondary structure in the target sequence?

    Yes. There are 'ALPHA', 'STRAND' and 'SHEET' restraint types that the model.restraints.make() command can generate. One specifies the segment which is then restrained to the specified secondary structure conformation. For example,

    from modeller.automodel import *
    
    # Redefine the special_restraints routine to include the secondary
    # structure restraints (this routine is empty by default):
    class mymodel(automodel):
        def special_restraints(self, aln):
            rsr = self.restraints
            # An alpha-helix:
            rsr.make(aln, restraint_type='ALPHA', residue_ids=('20', '30'),
                     spline_on_site=False)
            # Two strands:
            rsr.make(aln, restraint_type='STRAND', residue_ids=('1', '6'),
                     spline_on_site=False)
            rsr.make(aln, restraint_type='STRAND', residue_ids=('9', '14'),
                     spline_on_site=False)
            # An anti-parallel sheet:
            rsr.make(aln, restraint_type='SHEET', atom_ids=('N:1', 'O:14'),
                     sheet_h_bonds=-5, spline_on_site=False)
    
    log.verbose()
    env = environ()
    
    a = mymodel(env, alnfile='align1.ali', knowns='templ1', sequence='targ1')
    a.make()
    

  13. I want to patch the N-terminal or (C-terminal) residue (e.g., to model acetylation properly), but the model.patch() command does not work.

    This is probably because the N-terminus is patched by default with the NTER patching residue (corresponding to -NH3$^+$) and a patched residue must not be patched again. The solution is to turn the default patching off by env.patch_default = False before the model.generate_topology() command is called.

  14. Is it possible to use templates with the coordinates for ${C}_\alpha$ atoms only?

    Yes. You do not have to do anything special.

  15. How do I analyze the output log file?

    First, check for the error messages by searching for string '_E>''. These messages can only rarely be ignored. Next, check for the warning messages by searching for string '_W>''. These messages can almost always be ignored. If everything is OK so far, the most important part of the log file is the output of the model.energy() command for each model. This is where the violations of restraints are listed. When there are too many too violated restraints, more optimization or a different alignment is needed. What is too many and too much? It depends on the restraint type and is best learned by doing model.energy() on an X-ray structure or a good model to get a feel for it. You may also want to look at the output of command alignment.check(), which should be self-explanatory. I usually ignore the other parts of the log file.

  16. How do I prevent ``knots'' in the final models?

    The best way to prevent knots is to start with a starting structure that is as close to the desired final model as possible. Other than that, the only solution at this point is to calculate independently many models and hope that in some runs there won't be knots. Knots usually occur when one or more neighboring long insertions (i.e., longer than 15 residues) are modeled from scratch. The reason is that an insertion is build from a randomized distorted structure that is located approximately between the two anchoring regions. Under such conditions, it is easy for the optimizer to ``fall'' into a knot and then not be able to recover from it. Sometimes knots result from an incorrect alignment, especially when more than one template is used. When the alignment is correct, knots are a result of optimization not being good enough. However, making optimization more thorough by increasing the CPU time would not be worth it on the average as knots occur relatively infrequently. The excluded volume restraints are already included in the standard comparative modeling routine.

  17. What is considered to be the minimum length of a sequence motif necessary to derive meaningful constraints from the alignment to use in modeling.. one, two, three, or more?

    Usually more than that (dozens if you want just to detect reliable similarity, and even more if you want a real model). It is good to have at least 35-40% sequence identity to build a model. Sometimes even 30% is OK.

  18. Does Modeller have a graphical interface (GUI) ?

    No; Modeller is run from the command line, and uses a Python script to direct it. However, a graphical interface to Modeller is commercially available from Accelrys, as part of Discovery Studio Modeling 1.1, at http://www.accelrys.com/dstudio/ds_modeling/ds_modeler.html.

  19. What do the `Alignment sequence not found in PDB file' or `Number of residues in the alignment and pdb files are different' errors mean?

    When you give MODELLER an alignment, it also needs to read the structure of the known proteins (templates) from PDB files. In order to correctly match coordinates to the residues specified in the alignment, the sequences in the PDB file and the alignment file must be the same (although obviously you can add gap or chain break characters to your alignment). If they are not, you see this error. (Note that MODELLER takes the PDB sequence from the ATOM and HETATM PDB records, not the SEQRES records.) You should also check the header of your alignment file, to make sure that you are reading the correct chain and residue numbers from your PDB.

    To see the sequence that MODELLER reads from the PDB file '1BY8.pdb', use this short script to produce a '1BY8.seq' sequence file:

    env = environ()
    code = '1BY8'
    mdl = model(env, file=code)
    aln = alignment(env)
    aln.append_model(mdl, align_codes=code)
    aln.write(file=code+'.seq')
    

  20. Can I make a web interface to Modeller?

    Certainly, although you should bear in mind that the Modeller license is non-transferable, and permits free usage only for academic purposes. Visitors to your web interface must therefore obtain their own Modeller academic license key. You should provide a text box in your web interface into which users should put their license key, and then use that input to set the KEY_MODELLER8v2 environment variable, as is done by our own MODWEB and MODLOOP interfaces.


next up previous contents index