[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

[modeller_usage] A word on beta (strand) restraints



A few queries have come up over time on how to get Modeller to restrain
the model to an idealized beta strand, so here's a quick summary.

See http://salilab.org/modeller/FAQ6v2.html#19 for information on how to
specify secondary structure, including the 'STRAND' restraint type. This
adds additional restraints to those derived from the homology.

See http://salilab.org/modeller/manual6v2/node100.html for a description
of the types of restraints added for secondary structure. In summary,
both alpha and strand restraints add phi-psi restraints to force
residue mainchain conformation into class A (for helices) or B/P (for
strands). See modlib/mnch.lib for the representative dihedral angles of
these classes.

Note that Modeller attempts to fulfil all restraints, but violations
will often occur, particularly when conflicts between user-defined
and homology-derived restraints are present. This is less of a problem
with helix restraints than with strands, as helix restraints
enforce a number of distance restraints in addition to the phi-psi
restraints, and so are in a sense 'stronger'.

There is a bug in Modeller 6v2's generation of beta restraints; it
generates phi-phi restraints rather than the correct phi-psi restraints.
To correct this, take the .rsr file generated by Modeller. At the end of
this file should be some lines similar to the following for your beta
restraints (the following should be all on one line):

R    9   1   4  25   8   6   0   327   329   330   332   327   329   330
332      1.0000   -2.3387    2.5656    0.5271    0.3072   -0.6670

Notice that the atom indices for the phi dihedral angle (columns 9
through 12, 327   329   330   332) are the same as those for what should
be psi, columns 13 through 16. Correct the atom indices for psi, write
out the new .rsr file, and then use the recipe in
http://salilab.org/modeller/FAQ6v2.html#11 to override Modeller's
restraints with your corrected ones. If in doubt about the atom indices,
defining a helix restraint on the same residue range should yield the
correct values (the bug is only for strand restraints).

This bug is fixed in Modeller 7, which should be released in a few
weeks. Until then, apologies for the workaround!

	Ben Webb, Modeller Caretaker
-- 
             http://www.salilab.org/modeller/