[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: [modeller_usage] Question about alignment.align()



Vadim Patsalo wrote:
I am trying to take a pseudo-symmetric heterodimeric (AB) structure,
and build homodimer (AA) and (BB) structures. The chains have ~30-50%
identity, nearly the same in length.
The way I am doing this is aligning the AA sequence with the AB
sequence derived from the PDB with alignment.align(); However,
Modeller keeps doing something weird at the ends of the second chain,
placing breaks after the first and before the last residue. Chain A is
3 residues shorter than chain B. Example, with underscores inserted
instead of the actual sequence:

template  ___DLH/SVIEN___VNLED/../..
model     ___DLH/H-IAN___VDL-H/../..

I would expect to have the model be "-HIA" in the beginning and "DLH-"
at the end. This is the alignment that I get from Clustal, and the
alignment that makes sense to me. I've tried setting 'overhang=1',
using a number of different matrices from '$LIB', to no avail. With
other matrices (Gonnet), I get a _horrible_ alignment, like so:

VNLED/../..
VDLH/-../..

How could it insert a gap into a HETATM chain? Is there a better way
to do this, perhaps aligning only the chains that are changed in the
sequence (align A to B), instead of AA with AB?

I wouldn't recommend using align() for multi-chain alignments - it has no special handling of the chain breaks. I'd recommend instead doing separate alignments of each chain and then combining the results manually.

Non-standard residues are scored the same as glycine, so I'd not recommend trying to align HETATMs. It makes little sense anyway.

	Ben Webb, Modeller Caretaker
--
             http://www.salilab.org/modeller/